Use
weber.set Ceramic 6 is used for fixing ceramic, stone, clay and brick tiles to cement plaster and screeds, concrete and primed fibre cement surfaces.
- Suitable for walls and floors
- Suitable for interior and exterior use
The 6 hour set makes it ideal for quick installations.
Features & benefits
- Exceptional and consistent quality
- High strength
- Can be used on a wide range of surfaces
- Suitable for interior and exterior use
- Anti-slip properties
- 6 hour setting time
Technical data
- Initial setting time: approximately 3 hours
- Final setting time: approximately 6 hours
- Correction time: approximately 20 minutes
- Open time: approximately 20 minutes
- Pot life: approximately 40 minutes
- Grouting time: approximately 6 hours
- Water demand: 5 litres per 20 kg
- Temperature resistance: 5oC to 30oC during application, froes resistant when set
- Application temperatures: Do not apply in temperatures below 5oC or above 30oC
Note : all the data given was obtained at a temperature of 20oC and 50% relative humidity
Coverage
- 6m2 per 20kg bag when applied using a 6mm notched trowel.
- 4m2 per 20kg bag when applied when using a 10mm notched trowel.
Suitable surfaces
weber.set Ceramic 6 is suitable for use on surfaces like :
- Cement-based plaster
- Cement screeds
- Concrete surfaces
- Primed fibre cement surfaces
Note : the addition of weber.set Bond-it WB183 is required when:
- fixing low-porosity tiles
- movement or vibration is expected.
- fixing to walls above 2.5 metres high
Surface Preparation
The following minimum curing periods should be observed before tiling commences :
- New concrete floors : 28 days
- New screeds : 28 days
- New brick walls : 28 days
- New cement plaster : 28 days
Ensure that all surfaces are clean, dry, sound and free from dust, grease or any contamination that could impair bonding. Make good any unsound areas and remove flaky or peeling layers before tiling.
Organic growth must be removed and the spores killed using household bleach. PVA paint and gypsum plaster must be chipped to expose 80% of the substrate. Enamel paint and bitumen should be scraped and chipped to expose 80% of the substrate. Do not use a solvent or heat to remove bitumen from the surface.
Existing ceramic tiles must be thorooughly cleaned using undiluted weber.klin Tile Cleaner. Rinse using clean water.
Highly absorbant surfaces must be primed using a mix of 2 volumes of weber.prim Plaskey and 1 volume of weber.ad Key-It WB117. Apply to thickness of approximately 2mm using a block brush. Leave to dry for 24 hours.
General
- Tiles should be installed providing for adequate movement joints. Movement and expansion joints to be provided for at approximately 3 metre centres externally or at 4 metre centres internally, in both directions or as per the engineer’s specifications.
- All expansion and movement joints in the substrate must extend through the adhesive bed and tiles.
- Use only dry tiles - do not soak tiles.
Mixing
- Combine a 20kg bag of weber.set Ceramic 6 with 5 litres of clean water (and mix to a creamy paste). If less than the complete bag is used, the mix proportions are 5 parts by volume of powder to 2 parts by volume of water.
- Allow the mixture to mature for 5 minutes and re-mix thoroughly. The consistency can be adjusted by adding a small amount of water.
Do not add too much water or attempt to extend the working time by adding more water as this will cause the adhesive to be weak with a tendency to crumble.
Do not mix more adhesive than can be applied within 1 hour.
Application
Spread adhesive using a notched trowel to a minimum bedded thickness of 3mm on walls and 6mm on floors.
Heavily lugged, grooved or dove-tailed tiles must be buttered to fill any voids with adhesive before placing into wet adhesive.
Press tiles firmly into wet adhesive with a twisting action. Use a rubber mallet to bed large or heavy tiles.
Occasionally lift a tile to check that full contact is being made between the tile and the adhesive. Do not butt joint tiles.
Clean excess adhesive off the surface once tiles are firmly set using a damp sponge.
Once the adhesive has hardened, only mechanical removal is possible.
Minimum grouting joints for walls is 2mm and 3mm for floors.
Adhesive must be allowed to dry for 6 hours before grouting commences.
Grouting
Ensure that the joints are free from tile adhesive and any other foreign matter.
Allow 6 hours before grouting with weber.grout Tile Grout WB33. Allow 48 hours for sealed or non porous surfaces.
In wet or permanently wey conditions, replace the water and mix with weber.ad Bond-It WB183.
Storage
When stored, unopened in a dry place at temperatures above 5oC, shelf life is 6 to 9 months from date of manufacture.
Safety instructions
Contains cement, which is alkaline when wet and can cause skin
irritation. Use eye protection and gloves and avoid prolonged skin
contact. Avoid inhalation of dust. Wash skin contamination away
with warm soapy water. Remove splashes to the eyes by prolonged
irrigation and consult a doctor. Do not ingest.
Guarantee
We agree that Weber products meet the product specifications and will be free from any defect. Any guarantee with regard to the performance of Weber products will be subject to the professional and practical application of Weber products in accordance with our instructions and specifications.
However, we have no influence over specific site conditions and therefore, if in doubt, the user should first carry out sufficient tests to ensure that the product is suitable. In special cases, obtain advice.
Should our product prove defective, we undertake to replace any defective material. This guarantee will fall away in the event of Weber products being contaminated by the addition of sand, cement or substance other than recommended by us.
Technical services
Weber has a team of experienced advisors available to provide technical support.
Technical helpline : 0860 27 28 29 or visit www.weber-tylon.co.za
Saint-Gobain Construction Products SA (Pty) Ltd
77 Ostend Road, Germiston South, Johannesburg Tel.: +27 11 345-5300 Fax: +27 11 345-5301 Sales : 0860 27 28 29 or visit www.weber-tylon.co.za
To the best of our knowledge and belief, this information is true and accurate. As the conditions of use and any labour involved are beyond our control, the end-user must satisfy himself by prior testing that the product is suitable for his specific application. Products are sold subject to our Standard Conditions of Sale.
Product information
Packaging